Carrier EA36YD115 Expansion Valve
HomeStore

Carrier EA36YD115 Expansion Valve

Carrier EA36YD115 Expansion Valve

The Carrier EA36YD115 Expansion Valve is a high-performance R-410A thermal expansion valve designed for precision refrigerant metering in Carrier, Bryant, and Payne evaporator coils. Engineered as a genuine OEM replacement TXV, this component features a 3/8-inch ODF connection and is rated for systems ranging from 3.5 to 5 tons (up to 12 tons in specific commercial applications). By modulating refrigerant flow based on superheat levels, it prevents liquid slugging and ensures the compressor remains protected during high-demand cooling cycles.

This thermostatic expansion valve (TXV) utilizes a sensing bulb and external equalizer to maintain a balance between evaporator pressure and temperature. Its self-cleaning design minimizes the risk of TXV orifice clogging, a common point of failure in older systems. Replacing obsolete parts such as the LP318F and LPG16XF, the EA36YD115 provides a reliable solution for technicians troubleshooting low suction pressure or evaporator coil freezing issues. For optimal performance, ensure the sensing bulb is mounted at the 4 or 8 o'clock position on suction lines larger than 7/8 inches to achieve accurate refrigerant flow control.

Note: This item is Non Cancelable / Non Returnable.

Key Benefits for Technicians:
  • Direct OEM Compatibility: Precise fit for Carrier Infinity series and R-410A A-coils, eliminating the need for field modifications.
  • System Protection: Effectively manages evaporator superheat to prevent liquid refrigerant from entering and damaging the compressor.
  • Efficiency Enhancement: Optimizes the heat exchange process within the evaporator coil, maintaining SEER ratings and reducing energy consumption.
  • Durable Construction: Features a robust power head and high-grade copper connections for long-term reliability in high-vibration environments.
Common Questions:
  • What causes a TXV to "hunt" or fluctuate? Excessive hunting is often caused by an improperly positioned sensing bulb or an oversized valve. Ensure the bulb is insulated and securely strapped to the suction line for accurate readings.
  • Can this valve be used with refrigerants other than R-410A? While specifically optimized for R-410A refrigerant systems, always verify the pressure-temperature (P/T) chart and compatibility with your specific Carrier HVAC part requirements before installation.
  • How do I diagnose a failed-closed TXV? A valve failed in the closed position typically presents with high superheat at the evaporator outlet, low suction pressure, and possible frost at the valve outlet.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$109.16

Original: $311.89

-65%
Carrier EA36YD115 Expansion Valve

$311.89

$109.16

Carrier EA36YD115 Expansion Valve

The Carrier EA36YD115 Expansion Valve is a high-performance R-410A thermal expansion valve designed for precision refrigerant metering in Carrier, Bryant, and Payne evaporator coils. Engineered as a genuine OEM replacement TXV, this component features a 3/8-inch ODF connection and is rated for systems ranging from 3.5 to 5 tons (up to 12 tons in specific commercial applications). By modulating refrigerant flow based on superheat levels, it prevents liquid slugging and ensures the compressor remains protected during high-demand cooling cycles.

This thermostatic expansion valve (TXV) utilizes a sensing bulb and external equalizer to maintain a balance between evaporator pressure and temperature. Its self-cleaning design minimizes the risk of TXV orifice clogging, a common point of failure in older systems. Replacing obsolete parts such as the LP318F and LPG16XF, the EA36YD115 provides a reliable solution for technicians troubleshooting low suction pressure or evaporator coil freezing issues. For optimal performance, ensure the sensing bulb is mounted at the 4 or 8 o'clock position on suction lines larger than 7/8 inches to achieve accurate refrigerant flow control.

Note: This item is Non Cancelable / Non Returnable.

Key Benefits for Technicians:
  • Direct OEM Compatibility: Precise fit for Carrier Infinity series and R-410A A-coils, eliminating the need for field modifications.
  • System Protection: Effectively manages evaporator superheat to prevent liquid refrigerant from entering and damaging the compressor.
  • Efficiency Enhancement: Optimizes the heat exchange process within the evaporator coil, maintaining SEER ratings and reducing energy consumption.
  • Durable Construction: Features a robust power head and high-grade copper connections for long-term reliability in high-vibration environments.
Common Questions:
  • What causes a TXV to "hunt" or fluctuate? Excessive hunting is often caused by an improperly positioned sensing bulb or an oversized valve. Ensure the bulb is insulated and securely strapped to the suction line for accurate readings.
  • Can this valve be used with refrigerants other than R-410A? While specifically optimized for R-410A refrigerant systems, always verify the pressure-temperature (P/T) chart and compatibility with your specific Carrier HVAC part requirements before installation.
  • How do I diagnose a failed-closed TXV? A valve failed in the closed position typically presents with high superheat at the evaporator outlet, low suction pressure, and possible frost at the valve outlet.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Carrier EA36YD115 Expansion Valve is a high-performance R-410A thermal expansion valve designed for precision refrigerant metering in Carrier, Bryant, and Payne evaporator coils. Engineered as a genuine OEM replacement TXV, this component features a 3/8-inch ODF connection and is rated for systems ranging from 3.5 to 5 tons (up to 12 tons in specific commercial applications). By modulating refrigerant flow based on superheat levels, it prevents liquid slugging and ensures the compressor remains protected during high-demand cooling cycles.

This thermostatic expansion valve (TXV) utilizes a sensing bulb and external equalizer to maintain a balance between evaporator pressure and temperature. Its self-cleaning design minimizes the risk of TXV orifice clogging, a common point of failure in older systems. Replacing obsolete parts such as the LP318F and LPG16XF, the EA36YD115 provides a reliable solution for technicians troubleshooting low suction pressure or evaporator coil freezing issues. For optimal performance, ensure the sensing bulb is mounted at the 4 or 8 o'clock position on suction lines larger than 7/8 inches to achieve accurate refrigerant flow control.

Note: This item is Non Cancelable / Non Returnable.

Key Benefits for Technicians:
  • Direct OEM Compatibility: Precise fit for Carrier Infinity series and R-410A A-coils, eliminating the need for field modifications.
  • System Protection: Effectively manages evaporator superheat to prevent liquid refrigerant from entering and damaging the compressor.
  • Efficiency Enhancement: Optimizes the heat exchange process within the evaporator coil, maintaining SEER ratings and reducing energy consumption.
  • Durable Construction: Features a robust power head and high-grade copper connections for long-term reliability in high-vibration environments.
Common Questions:
  • What causes a TXV to "hunt" or fluctuate? Excessive hunting is often caused by an improperly positioned sensing bulb or an oversized valve. Ensure the bulb is insulated and securely strapped to the suction line for accurate readings.
  • Can this valve be used with refrigerants other than R-410A? While specifically optimized for R-410A refrigerant systems, always verify the pressure-temperature (P/T) chart and compatibility with your specific Carrier HVAC part requirements before installation.
  • How do I diagnose a failed-closed TXV? A valve failed in the closed position typically presents with high superheat at the evaporator outlet, low suction pressure, and possible frost at the valve outlet.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

You may also like

-65%NEW
Thumbnail 1

Carrier P032-3121 Compressor

$2,063.49

$722.22

-65%NEW
Thumbnail 1

Carrier P032-1524 Compressor

$11,800.00

$4,130.00

-65%NEW
Thumbnail 1

Carrier P031-7171 Compressor

$3,452.14

$1,208.25

-65%NEW
Thumbnail 1

Carrier P031-6871 Compressor

$3,452.14

$1,208.25

-65%NEW
Thumbnail 1

Carrier P031-4951 Compressor

$3,315.42

$1,160.40

-65%NEW
Thumbnail 1

Carrier P031-4151 Compressor

$3,117.56

$1,091.15

-65%NEW
Thumbnail 1

Carrier P031-4171 Compressor

$4,184.73

$1,464.66

-65%NEW
Thumbnail 1

Carrier P031-3223 Compressor

$1,533.65

$536.78

NEW
Thumbnail 1

Carrier P035-0924 Compressor

$11,800.00

-65%NEW
Thumbnail 1

Carrier P032-5854 Compressor

$11,800.00

$4,130.00

NEW
Thumbnail 1

Carrier P035-2021 Compressor

$1,054.92

NEW
Thumbnail 1

Carrier P291-0504 Run Capacitor

$6.06