Bard HVAC EHWH24B-C06 Heat Strip
HomeStore

Bard HVAC EHWH24B-C06 Heat Strip

Bard HVAC EHWH24B-C06 Heat Strip

The Bard EHWH24B-C06 is a field-installable electric heater package designed specifically for integration with 2-ton Bard wall-mount heat pumps. This 6kW heat strip operates on a 208/230V single-phase power supply, providing critical supplemental heat and allowing for efficient emergency heat functionality when ambient temperatures drop below the heat pump's balance point. Engineered for precise fitment in the blower discharge section, the EHWH24B-C06 utilizes high-grade nichrome heating elements and includes integrated thermal limit protection to ensure safe operational parameters. For contractors, this unit simplifies HVAC preventative maintenance and system upgrades by utilizing a plug-and-play wiring harness, reducing field labor time and ensuring a secure electrical connection to the Bard wall-mount unit. This heater kit is essential for maintaining discharge air temperatures during defrost cycles in commercial HVAC maintenance applications.

Key Benefits

  • Compatible with Bard 2-ton heat pump models including the W24H and T24H series.
  • Provides 6kW supplemental heating capacity to meet specific building heat load requirements.
  • Features a built-in circuit breaker for simplified overcurrent protection and localized disconnect.
  • Constructed with heavy-gauge steel and corrosion-resistant components for long-term service in industrial climate control environments.
  • Engineered for rapid installation with a factory-provided wiring harness and straightforward mounting brackets.

Common Questions

What is the minimum circuit ampacity (MCA) for the EHWH24B-C06?
When installing this 6kW electric heat kit, technicians must verify the nameplate data on the specific wall-mount unit, as the MCA will vary based on the combination of the heater and the blower motor amperage.

Can this heater be used for emergency heat cycles?
Yes, the Bard EHWH24B-C06 is designed to act as the primary heat source during emergency heat mode should the compressor fail or when the outdoor temperature is too low for efficient heat pump operation.

Does this kit include the required circuit breakers?
The EHWH24B-C06 typically comes equipped with a 60-amp toggle-style circuit breaker, which serves as both a safety disconnect and overcurrent protection for the high-voltage circuit.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$197.76

Original: $565.02

-65%
Bard HVAC EHWH24B-C06 Heat Strip

$565.02

$197.76

Bard HVAC EHWH24B-C06 Heat Strip

The Bard EHWH24B-C06 is a field-installable electric heater package designed specifically for integration with 2-ton Bard wall-mount heat pumps. This 6kW heat strip operates on a 208/230V single-phase power supply, providing critical supplemental heat and allowing for efficient emergency heat functionality when ambient temperatures drop below the heat pump's balance point. Engineered for precise fitment in the blower discharge section, the EHWH24B-C06 utilizes high-grade nichrome heating elements and includes integrated thermal limit protection to ensure safe operational parameters. For contractors, this unit simplifies HVAC preventative maintenance and system upgrades by utilizing a plug-and-play wiring harness, reducing field labor time and ensuring a secure electrical connection to the Bard wall-mount unit. This heater kit is essential for maintaining discharge air temperatures during defrost cycles in commercial HVAC maintenance applications.

Key Benefits

  • Compatible with Bard 2-ton heat pump models including the W24H and T24H series.
  • Provides 6kW supplemental heating capacity to meet specific building heat load requirements.
  • Features a built-in circuit breaker for simplified overcurrent protection and localized disconnect.
  • Constructed with heavy-gauge steel and corrosion-resistant components for long-term service in industrial climate control environments.
  • Engineered for rapid installation with a factory-provided wiring harness and straightforward mounting brackets.

Common Questions

What is the minimum circuit ampacity (MCA) for the EHWH24B-C06?
When installing this 6kW electric heat kit, technicians must verify the nameplate data on the specific wall-mount unit, as the MCA will vary based on the combination of the heater and the blower motor amperage.

Can this heater be used for emergency heat cycles?
Yes, the Bard EHWH24B-C06 is designed to act as the primary heat source during emergency heat mode should the compressor fail or when the outdoor temperature is too low for efficient heat pump operation.

Does this kit include the required circuit breakers?
The EHWH24B-C06 typically comes equipped with a 60-amp toggle-style circuit breaker, which serves as both a safety disconnect and overcurrent protection for the high-voltage circuit.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Bard EHWH24B-C06 is a field-installable electric heater package designed specifically for integration with 2-ton Bard wall-mount heat pumps. This 6kW heat strip operates on a 208/230V single-phase power supply, providing critical supplemental heat and allowing for efficient emergency heat functionality when ambient temperatures drop below the heat pump's balance point. Engineered for precise fitment in the blower discharge section, the EHWH24B-C06 utilizes high-grade nichrome heating elements and includes integrated thermal limit protection to ensure safe operational parameters. For contractors, this unit simplifies HVAC preventative maintenance and system upgrades by utilizing a plug-and-play wiring harness, reducing field labor time and ensuring a secure electrical connection to the Bard wall-mount unit. This heater kit is essential for maintaining discharge air temperatures during defrost cycles in commercial HVAC maintenance applications.

Key Benefits

  • Compatible with Bard 2-ton heat pump models including the W24H and T24H series.
  • Provides 6kW supplemental heating capacity to meet specific building heat load requirements.
  • Features a built-in circuit breaker for simplified overcurrent protection and localized disconnect.
  • Constructed with heavy-gauge steel and corrosion-resistant components for long-term service in industrial climate control environments.
  • Engineered for rapid installation with a factory-provided wiring harness and straightforward mounting brackets.

Common Questions

What is the minimum circuit ampacity (MCA) for the EHWH24B-C06?
When installing this 6kW electric heat kit, technicians must verify the nameplate data on the specific wall-mount unit, as the MCA will vary based on the combination of the heater and the blower motor amperage.

Can this heater be used for emergency heat cycles?
Yes, the Bard EHWH24B-C06 is designed to act as the primary heat source during emergency heat mode should the compressor fail or when the outdoor temperature is too low for efficient heat pump operation.

Does this kit include the required circuit breakers?
The EHWH24B-C06 typically comes equipped with a 60-amp toggle-style circuit breaker, which serves as both a safety disconnect and overcurrent protection for the high-voltage circuit.