The Automation Components Inc (ACI) FS-6 Freeze Stat is a high-performance low limit controller engineered for precision freeze protection within commercial HVACR systems. This 6 foot capillary thermostat utilizes a vapor-filled sensing element to detect the lowest temperature across any one-foot section, providing a critical failsafe for heating and cooling coils. Equipped with 2-SPDT (Double Pole Double Throw) contacts, the FS-6 allows for simultaneous system shutdown and alarm signaling, ensuring immediate response to potential freezing conditions. As a manual reset freeze stat, it requires technician intervention after a trip, facilitating a necessary system check to identify the root cause of the temperature drop. The adjustable setpoint range of 14° to 54°F and its robust NEMA 1 enclosure make it a versatile HVAC low limit switch for protecting equipment against thermal stratification and airborne temperature drops.

High-Volume SEO Keywords: ACI FS-6, freeze stat, low limit controller, HVAC freeze protection, manual reset thermostat

Conversational Queries:

  • How do I install a 6-foot ACI freeze stat on a cooling coil?
  • What is the difference between manual and automatic reset freeze stats?
  • Why is my ACI FS-6 low limit switch tripping in the winter?
Key Benefits:
  • Dual-Circuit Protection: Features 2-SPDT contacts for independent control of equipment shutdown and remote alarm notification.
  • Reliable Sensing: The 6-foot vapor-charged copper capillary responds to the coldest point along its length for comprehensive coverage.
  • Enhanced Safety: The manual reset design prevents automatic system restarts, ensuring a technician inspects the unit after a freeze event.
  • Field Adjustable: Easily configure the trip point between 14°F and 54°F to meet specific environmental requirements.
  • Industrial Durability: Housed in a NEMA 1 rated enclosure with a wide operating humidity range of 0 to 95% non-condensing.
Common Questions:
  • Can this unit be mounted in any orientation? Yes, the ACI FS-6 can be duct-mounted or installed across coils, but the capillary must be positioned where it can sense the coldest air first.
  • What does the 2-SPDT output allow me to do? It allows you to break the circuit to the fan or compressor while simultaneously closing a circuit to a building management system (BMS) or local strobe.
  • Is the sensing element flexible? Yes, the copper capillary is designed to be snaked across the face of a coil to monitor for temperature stratification.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

This item is not eligible for free shipping.

$257.51
Automation Components Inc (ACI) FS-6 Freeze Stat
$257.51

Automation Components Inc (ACI) FS-6 Freeze Stat

The Automation Components Inc (ACI) FS-6 Freeze Stat is a high-performance low limit controller engineered for precision freeze protection within commercial HVACR systems. This 6 foot capillary thermostat utilizes a vapor-filled sensing element to detect the lowest temperature across any one-foot section, providing a critical failsafe for heating and cooling coils. Equipped with 2-SPDT (Double Pole Double Throw) contacts, the FS-6 allows for simultaneous system shutdown and alarm signaling, ensuring immediate response to potential freezing conditions. As a manual reset freeze stat, it requires technician intervention after a trip, facilitating a necessary system check to identify the root cause of the temperature drop. The adjustable setpoint range of 14° to 54°F and its robust NEMA 1 enclosure make it a versatile HVAC low limit switch for protecting equipment against thermal stratification and airborne temperature drops.

High-Volume SEO Keywords: ACI FS-6, freeze stat, low limit controller, HVAC freeze protection, manual reset thermostat

Conversational Queries:

  • How do I install a 6-foot ACI freeze stat on a cooling coil?
  • What is the difference between manual and automatic reset freeze stats?
  • Why is my ACI FS-6 low limit switch tripping in the winter?
Key Benefits:
  • Dual-Circuit Protection: Features 2-SPDT contacts for independent control of equipment shutdown and remote alarm notification.
  • Reliable Sensing: The 6-foot vapor-charged copper capillary responds to the coldest point along its length for comprehensive coverage.
  • Enhanced Safety: The manual reset design prevents automatic system restarts, ensuring a technician inspects the unit after a freeze event.
  • Field Adjustable: Easily configure the trip point between 14°F and 54°F to meet specific environmental requirements.
  • Industrial Durability: Housed in a NEMA 1 rated enclosure with a wide operating humidity range of 0 to 95% non-condensing.
Common Questions:
  • Can this unit be mounted in any orientation? Yes, the ACI FS-6 can be duct-mounted or installed across coils, but the capillary must be positioned where it can sense the coldest air first.
  • What does the 2-SPDT output allow me to do? It allows you to break the circuit to the fan or compressor while simultaneously closing a circuit to a building management system (BMS) or local strobe.
  • Is the sensing element flexible? Yes, the copper capillary is designed to be snaked across the face of a coil to monitor for temperature stratification.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

This item is not eligible for free shipping.

Product Information

Shipping & Returns

Description

The Automation Components Inc (ACI) FS-6 Freeze Stat is a high-performance low limit controller engineered for precision freeze protection within commercial HVACR systems. This 6 foot capillary thermostat utilizes a vapor-filled sensing element to detect the lowest temperature across any one-foot section, providing a critical failsafe for heating and cooling coils. Equipped with 2-SPDT (Double Pole Double Throw) contacts, the FS-6 allows for simultaneous system shutdown and alarm signaling, ensuring immediate response to potential freezing conditions. As a manual reset freeze stat, it requires technician intervention after a trip, facilitating a necessary system check to identify the root cause of the temperature drop. The adjustable setpoint range of 14° to 54°F and its robust NEMA 1 enclosure make it a versatile HVAC low limit switch for protecting equipment against thermal stratification and airborne temperature drops.

High-Volume SEO Keywords: ACI FS-6, freeze stat, low limit controller, HVAC freeze protection, manual reset thermostat

Conversational Queries:

  • How do I install a 6-foot ACI freeze stat on a cooling coil?
  • What is the difference between manual and automatic reset freeze stats?
  • Why is my ACI FS-6 low limit switch tripping in the winter?
Key Benefits:
  • Dual-Circuit Protection: Features 2-SPDT contacts for independent control of equipment shutdown and remote alarm notification.
  • Reliable Sensing: The 6-foot vapor-charged copper capillary responds to the coldest point along its length for comprehensive coverage.
  • Enhanced Safety: The manual reset design prevents automatic system restarts, ensuring a technician inspects the unit after a freeze event.
  • Field Adjustable: Easily configure the trip point between 14°F and 54°F to meet specific environmental requirements.
  • Industrial Durability: Housed in a NEMA 1 rated enclosure with a wide operating humidity range of 0 to 95% non-condensing.
Common Questions:
  • Can this unit be mounted in any orientation? Yes, the ACI FS-6 can be duct-mounted or installed across coils, but the capillary must be positioned where it can sense the coldest air first.
  • What does the 2-SPDT output allow me to do? It allows you to break the circuit to the fan or compressor while simultaneously closing a circuit to a building management system (BMS) or local strobe.
  • Is the sensing element flexible? Yes, the copper capillary is designed to be snaked across the face of a coil to monitor for temperature stratification.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.