Amana-Goodman TX5N2 TXV
The Amana-Goodman TX5N2 TXV is a precision-engineered thermostatic expansion valve (TXV) designed to optimize refrigerant flow in high-efficiency HVAC systems. Specifically tailored for 3.5-5 Ton R-22 applications, this non-bleed TXV kit ensures that your air conditioning or heat pump unit maintains the exact superheat required for peak performance. By utilizing a pressure-sensing bulb to modulate the flow of liquid refrigerant into the evaporator coil, the TX5N2 prevents liquid slugging and enhances heat transfer efficiency. Constructed with durable materials for long-term reliability in various environments, this direct OEM replacement part is critical for restoring system capacity and reducing energy consumption in older R-22 residential and light commercial units.
Key Benefits:- Optimized Efficiency: Maintains precise refrigerant metering to maximize cooling capacity and system SEER ratings.
- Broad Compatibility: Engineered for use with 3.5-ton to 5-ton Goodman and Amana evaporators using R-22 refrigerant.
- Non-Bleed Design: Features a non-bleed valve mechanism that maintains pressure during the off-cycle, supporting faster cooling upon startup.
- System Longevity: Protects the compressor from damage by preventing liquid refrigerant from returning to the suction line.
- Easy Installation: The TX5N2 kit includes the necessary components for a standard field installation or replacement.
- Can I use the TX5N2 with R-410A refrigerant? No, the TX5N2 is specifically calibrated for R-22 refrigerant systems and should not be used with R-410A.
- Will this valve fit a 3-ton unit? This specific model is designed for 3.5 to 5-ton systems; using it on smaller tonnage units may lead to improper refrigerant metering.
- Does this kit require brazing? Yes, professional HVAC installation involving brazing is typically required to ensure a leak-free connection to the liquid line.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
This item is not eligible for free shipping.
Amana-Goodman TX5N2 TXV
The Amana-Goodman TX5N2 TXV is a precision-engineered thermostatic expansion valve (TXV) designed to optimize refrigerant flow in high-efficiency HVAC systems. Specifically tailored for 3.5-5 Ton R-22 applications, this non-bleed TXV kit ensures that your air conditioning or heat pump unit maintains the exact superheat required for peak performance. By utilizing a pressure-sensing bulb to modulate the flow of liquid refrigerant into the evaporator coil, the TX5N2 prevents liquid slugging and enhances heat transfer efficiency. Constructed with durable materials for long-term reliability in various environments, this direct OEM replacement part is critical for restoring system capacity and reducing energy consumption in older R-22 residential and light commercial units.
Key Benefits:- Optimized Efficiency: Maintains precise refrigerant metering to maximize cooling capacity and system SEER ratings.
- Broad Compatibility: Engineered for use with 3.5-ton to 5-ton Goodman and Amana evaporators using R-22 refrigerant.
- Non-Bleed Design: Features a non-bleed valve mechanism that maintains pressure during the off-cycle, supporting faster cooling upon startup.
- System Longevity: Protects the compressor from damage by preventing liquid refrigerant from returning to the suction line.
- Easy Installation: The TX5N2 kit includes the necessary components for a standard field installation or replacement.
- Can I use the TX5N2 with R-410A refrigerant? No, the TX5N2 is specifically calibrated for R-22 refrigerant systems and should not be used with R-410A.
- Will this valve fit a 3-ton unit? This specific model is designed for 3.5 to 5-ton systems; using it on smaller tonnage units may lead to improper refrigerant metering.
- Does this kit require brazing? Yes, professional HVAC installation involving brazing is typically required to ensure a leak-free connection to the liquid line.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
This item is not eligible for free shipping.
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
The Amana-Goodman TX5N2 TXV is a precision-engineered thermostatic expansion valve (TXV) designed to optimize refrigerant flow in high-efficiency HVAC systems. Specifically tailored for 3.5-5 Ton R-22 applications, this non-bleed TXV kit ensures that your air conditioning or heat pump unit maintains the exact superheat required for peak performance. By utilizing a pressure-sensing bulb to modulate the flow of liquid refrigerant into the evaporator coil, the TX5N2 prevents liquid slugging and enhances heat transfer efficiency. Constructed with durable materials for long-term reliability in various environments, this direct OEM replacement part is critical for restoring system capacity and reducing energy consumption in older R-22 residential and light commercial units.
Key Benefits:- Optimized Efficiency: Maintains precise refrigerant metering to maximize cooling capacity and system SEER ratings.
- Broad Compatibility: Engineered for use with 3.5-ton to 5-ton Goodman and Amana evaporators using R-22 refrigerant.
- Non-Bleed Design: Features a non-bleed valve mechanism that maintains pressure during the off-cycle, supporting faster cooling upon startup.
- System Longevity: Protects the compressor from damage by preventing liquid refrigerant from returning to the suction line.
- Easy Installation: The TX5N2 kit includes the necessary components for a standard field installation or replacement.
- Can I use the TX5N2 with R-410A refrigerant? No, the TX5N2 is specifically calibrated for R-22 refrigerant systems and should not be used with R-410A.
- Will this valve fit a 3-ton unit? This specific model is designed for 3.5 to 5-ton systems; using it on smaller tonnage units may lead to improper refrigerant metering.
- Does this kit require brazing? Yes, professional HVAC installation involving brazing is typically required to ensure a leak-free connection to the liquid line.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
This item is not eligible for free shipping.